malfunctions (sensor failed or magnet missing) or the stepping-motor isdefective (or its
driver circuit on the main PCB). The focus motor is not located in the defaultposition after the
reset.
Cyan Color Er
(Cyan Color-wheel error) This message will appear after the reset of the fixture if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its drive circuit on the main PCB). The Cyan Color wheel is
not located in the default position after the reset.
Magenta Color Er
(Magenta Color-wheel error) This message will appear after the reset of the fixture if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its drive circuit on the main PCB). The Magenta Color-wheel
is not located in the default position after the reset.
Yellow Color Er
(Yellow Color-wheel error) This message will appear after the reset of the fixture and if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driver circuit on the main PCB). The Yellow Color - wheel
is not located in the default position after the reset.
ZOOM Er
(ZOOM-wheel error) This message will appear after the reset of the fixture and if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driver circuit on the main PCB). The zoom - wheel is not